Retour d’expérience clinique à propos des 200 premiers patients traités au MRIdian® à l’Institut Paoli-Calmettes - 09/11/21

Start of activity with the MRIdian® system: The first 200 patients treated at the Institut Paoli-Calmettes

Doi : 10.1016/j.bulcan.2021.05.013 
Marguerite Tyran , Pierre Fau, Hugues Mailleux, Pierre Eustache, Mohamed Benkreira, Naji Salem, Véronique Favrel, Laurence Gonzague, Laurence Moureau-Zabotto, Leonel Varela, Pierre Annede, Agnes Tallet
 Institut Paoli-Calmettes, radiothérapie, 232, boulevard Sainte Marguerite, 19009 Marseille, France 

Marguerite Tyran, Institut Paoli-Calmettes, radiothérapie, 232, boulevard Sainte Marguerite, 19009 Marseille, France.Institut Paoli-Calmettes, radiothérapie232, boulevard Sainte MargueriteMarseille19009France

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 9
Iconographies 2
Vidéos 0
Autres 0

Résumé

Introduction

Plusieurs centres se sont récemment équipés de systèmes de radiothérapie guidés par IRM dont l’institut Paoli-Calmettes. Nous rapportons notre retour d’expérience.

Méthodes

Des données relatives aux traitements sur le MRIdian® (Viewray®) ont été recueillies prospectivement. Les démarches concernant la qualité et les problématiques organisationnelles engagées dans le service ont été synthétisées.

Résultats

Entre février 2019 et mars 2020, 201 patients ont été simulés : 40 % des traitements étaient normofractionnés (n=70) et 60 % hypofractionnés (n=105). Le taux d’occupation mensuel de l’appareil était au premier, sixième et douzième mois de 30 %, 62 % et 90 %. La répartition des traitements normofractionnés est dominée par les néoplasies prostatiques (29 %) et pancréatiques (26 %) suivis des cancers gynécologiques (12 %) ou des rechutes ganglionnaires (12 %) et de surimpressions pour des cancers du rectum/vagin (11 %). Concernant les traitements en hypofractionnement modéré (dose par fraction entre 3 et 5Gy), ils correspondaient majoritairement à des boost-intégrés pour des rechutes oligo-métastatiques ganglionnaires (11 %), alors que les traitements stéréotaxiques concernaient en priorité des lésions osseuses (30 %) puis hépatiques (15 %).

Discussion

Le MRIdian® a été utilisé initialement de façon large correspondant à une courbe d’apprentissage pour maîtriser le guidage IRM. Cette modalité d’IGRT, en apportant de nouvelles solutions tant pour les mouvements inter qu’intrafraction, sécurise des réductions de marge supplémentaires afin de mieux protéger les organes-à-risque. La nouveauté apportée par le MRDian® à notre plateau technique est la possibilité de faire de la radiothérapie adaptative en temps réel dont la mise en route a été plus progressive.

Le texte complet de cet article est disponible en PDF.

Summary

Introduction

Several centers have recently been equipped with MRI-guided radiotherapy systems, including the Paoli-Calmettes Institute which was the first French center to start this activity. We report in this article our early experience.

Methods

Data related to patients treated on the MRIdian® (Viewray®) were prospectively collected. Procedures concerning the implementation of the system and internal organizational issues were summarized.

Results

Between February 2019 and March 2020, 201 patients were treated: 40% of treatments were normofractionated (n=70) and 60% used hypofractionation (n=105). The reported monthly occupancy rate at one, six and twelve months was 30%, 62%, and 90%. The distribution of normofractionated treatments was dominated by prostatic (29%) and pancreatic (26%) cancers, followed by abdomino-pelvic irradiations for gynecological cancers (12%) or lymph node diseases (12%) and boosts for rectal or vaginal cancers (11%). Regarding treatments with moderate hypofractionation (dose by fraction between 3 and 5Gy), they corresponded mainly to integrated boost for abdomino-pelvic lymph nodes (38%), while the stereotaxic treatments primarily concerned hepatic lesions (15%), bones (30%).

Discussion

The MRIdian® was initially used widely in our service corresponding to a learning curve for MRI guidance. This new tool for image-guided radiotherapy helped us to secure our practice providing solutions for both inter and intra-fraction movements making it possible to reduce the additional margin in order to better protect the organs at risk. The main technical difference with conventional accelerators is the possibility of performing adaptive radiotherapy in real time, the start of which was more gradual.

Le texte complet de cet article est disponible en PDF.

Mots clés : Radiothérapie guidée par IRM, Démarrage d’activité, Expérience clinique

Keywords : MR-guided radiotherapy, Start of activity, Clinical experience


Plan


 Travail présenté au congrès annuel de la SFRO 2020.


© 2021  Société Française du Cancer. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 108 - N° 11

P. 1010-1018 - novembre 2021 Retour au numéro
Article précédent Article précédent
  • Chirurgie de réduction de risque mammaire et découverte fortuite de cancer : dix ans d’expérience dans un centre de lutte contre le cancer
  • Manon Mangiardi-Veltin, Foucauld Chamming's, Anne Jaffre, Aurélien Rousvoal, Christine Tunon de Lara, Véronique Brouste, Stéphanie Hoppe, Claire Sénéchal
| Article suivant Article suivant
  • Naissance du bilan éducatif partagé unique et commun à l’Institut Curie
  • Carole Kalogéropoulos, Silène Delorme, Claire Llambrich-Molines, Nicolas Girard, Evelyne Renault-Tessier

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.